Material to be processed | Dry, dust-free, classified (contents of main class 85% minimum) |
Material grain size fraction | -6+3,-3+1, -1+0.5 |
Material supply and transportation system
| Grain-by-grain, 4-stream, one-stage type with feeding vibrofeeder and stretching vibrofeeder.
Optional installation of collectors (tanks) for concentrate and tailings. |
Throughput |
50 kg/h (-6+3)
12.5 kg/h (-3+1)
2 kg/h(-1+0.5) |
X-ray: |
number of X-ray tubes | 1 |
mode of radiation | Pulse type (pulse duration - 0.5 ms; pulse period - 4 ms) |
anode voltage, anode current | (33-2) kV max.; (330±10) mA |
Detection: |
Single-sided material luminescence detection.
Analogue-to-Digital Processing System; operation both in amplitude-time mode and in special mode - increased selectivity using kinetic features of luminescence (extra selection effect is ensured by luminescent-absorption analysis mode).
Higher sensitivity and selectivity is provided than with LS-OD-4-04N sorter. |
luminescent signals' receivers | photomultiplier tubes (PMT) |
number of detectors, detection channels | 4 (one per each channel) |
Ejection | Pneumatic, with compressed air, by means of solenoid-operated pneumatic valves.
4-channel stopping mechanism. Channel-by-channel ejection. |
Recovery rate |
98% (-6+3mm),
96% (-3+1mm),
90% (-1+0.5mm) |
Yield per 10 ejections 30 grains
|
30 grains (-6+3 mm),
45 grains (-3+1 mm),
45 grains (-1+0.5 mm) |
Automation | Checking of main systems prior to start of material supply and in the course of operation (material supply is stopped if fault is detected). Sensitivity control. Failure indication. Monitoring and control from the APCS of enrichment plant. Protection system against unauthorized access to SM, material only if special smart cards are available. |
Electric power supply | 1 phase; (220±22) V; (50±1) Hz |
Power consumption | 3 kVA max. |
Volumentric flowrate of potable water to cool the tubes | 6 l/min minimum |
Average compressed air flowrate | 120l/min |
Overall dimensions (L×W×H), weigth: |
SM | 1190×730×1690 mm, 700 kg |
ACR | 765×550×1745 mm, 230 kg |
Operation Conditions: |
Ambient air temperature | from + 10°С to + 35°С |
Relative humidity (at ambient air temperature + 25°С) | 80% max. |
Protection against X-rays | Specially designed construction of the sorter totally protects against the X-ray. Each unit is being tested for safety. |